Image
H-BOP Series Blowout Preventer Safety Female Plug

H6F6-BOP - H-BOP Series Blowout Preventer Safety Female Plug

Dixon Distributor? 

Log in to view pricing, inventory, place orders & much more. If you want to create an account, please click the button to begin the registration process.

Attributes

Maximum Operating Pressure
5,000 PSI (345 Bar)
Weight
0.45 lb
Break Quantity
1
Optional Package/Box Quantity
1
Material
Steel
Maximum OD
1.44" (36.6 mm)
Thread
Female NPTF
Seal
FKM
Body Size
3/4"
Burst Pressure
16,500 PSI (1,150 Bar)
Thread Size
3/4" - 14
Length
2.41" (61.2 mm)
Hex
1-5/16"
Flow
29 GPM

Details

Applications

Designed specifically for blow-out prevention systems on drilling rigs

Compatibility & Interchange Data

  • Eaton/Hansen HKFR-Series
  • DNP HNV-BOP Series
  • Interchangeable to ISO7241 Series B

Construction

  • Machined components are manufactured using solid steel bar stock
  • Stainless steel balls, retaining rings, and springs maximize corrosion resistance and extend service life.
  • Steel components are plated using ROHS Compliant Trivalent Chrome
  • Steel nipples are hardened to provide heavy duty performance and resist brinneling.
  • Red powder coated coupler sleeve for easy BOP service identification, locking sleeve is standard
  • Blow-out Preventer (BOP) coupling critical seals are severe service FKM
  • PTFE Anti-Extrusion ring protects main coupling valve seal from dynamic impulse pressure damage
  • Valve seals are crimped in place to maintain integrity during excessive flow conditions and pressurized connection
  • Individually marked with the BOP series designation

Specifications

  • BOP couplings have been fire tested and Lloyd's certified to 700°C (1300°F) in accordance with API 16D. Certificate available upon request.
  • Flow ΔP = 22 PSI
  • Lloyd's Test Pressure: 5,000 PSI
WARNING: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.

Resources

    Request a Quote

    Need help selecting the correct components?